JLS Series - Diaphragm Metering Pump
Main Application
Various fields such as oil and chemical industry, chemical industry, electricity, metallurgy, etc., especially in high-precision and high-pressure fields.
Product Info & Specification
Design Features & Applications
Main performance parameters
maximum flow rate: 240L/h
Maximum discharge pressure: 13Mpa
Adjustment range: 10%-100% steady-state accuracy ±1%
Suction and lifting height: 2.5m
Medium temperature: -10°C ~ 100°C
The maximum ambient temperature is ±40°C
Control Mode
Power supply: 380V/three-phase, 220V/single-phase, 220/three-phase, 50Hz/60Hz. By installing a variable frequency controller to receive external control signals, the stroke speed can be adjust.
Input signal: 4-20mA analog signal
The switch controller controls the three-phase motor in an "on/off" manner to regulate the output flow rate.